Material Environment Friendly WPC Decoration Products

Teach you how to distinguish floor heating floor, far away from buying mistake

"Is the name of the dedicated geothermal floor right?"

Current circulation of the floor on the market for heating floor, not only sort is various, and the name of the more disorderly, such as "heat" floor "floor" heat resistant "to heat the floor" and so on, is called the most is "heating floor" "heating floor" "heat resistant floor" "floor" heat "special geothermic floor", etc., we think some name, not science, some name seems to be not appropriate, the radiant floor heating system, especially early is booming, the name must be standardized, should say: "floor of floor heating is its definition should be:" applies to the ground laid wood floor radiation heating system, and through the plate heat transfer for the bedroom.


"Do all the floors have floor heating?"

"Your floor can do floor heating?" The director replies: "absolutely no problem, geothermal special floor." Almost every person that sells the floor is so very affirmative answer, also take out user instance, some still produce test report, so consumer feels, "all the floor should do floor warm floor." There are four main factors that can be used to meet the needs of earth heating: thermal conductivity, dimensional stability, pollution prevention and environmental protection, and durability. Floor industry is developing floor standard, make four elements quantization, and make floor laid and guarantee period quality inspection standard, make laid, maintain technical index also quantified.

"Is the floor thicker and warmer?"

The thickness of the wood floor is to determine whether the foot feels comfortable, so many consumers in the floor of choose and buy, especially the real wood of choose and buy when multi-layer solid wood or bamboo floor requires 15 to 18 mm in thickness. When floor heating floor of choose and buy, therefore, they also use this method to select, but little imagine wood belongs to the poor conductor, usually of the wood material coefficient of thermal conductivity between 0.17 0.34, and the water is 0.5. If the thickness of the floor is too thick, it is more unfavourable for heat to pass through the floor to the board, and it is consumed in the conduction process. As for heat preservation, up and down the floor temperature difference is very big, will inevitably lead to the floor deformation is large, the heat bilges cold shrink "wet bilge drying shrinkage will cause the floor" gourd ladle, twisting, bending, cracking, dimension stability is not guaranteed.

"Is the floor specification too wide?"

Now consumer buys real wood floor one is to live comfortable, 2 is to reveal oneself identity. Therefore, in the selection of the large size of the floor, especially the width direction, some can reach 180mm. This width in the daily floor shop experts doesn't recommend that users choose and buy, lest appear because the floor is wet bilge drying shrinkage from the seam, and on the floor under the condition of heating because the water sends out faster, are more prone to leave seam floor. So, the expert advises the consumer to choose the floor that does not want to buy the floor with excessive size as far as possible.

"Can you only levitate?"

Because of the special structure of the geothermal heating system, the concrete floor cannot be nailed when the floor is laid. Therefore, the pavement of the geothermal floor has long been known as the suspension laying method. In fact, with the continuous improvement of science and technology, there are two other ways of laying: floor bonding and keel laying. Recently appeared on the market a -- -- -- -- -- - fast loading keel, the keel of the shop is not inevitable, you can use glue will keel fixed directly on the cement ground, and then through the card buckle on the keel, to fix the floor on the keel. Such not only can increase the foot feeling of the floor, and, due to leave space between the keel, make the air convection can up and down on the floor, is conducive to the cycle of heat convection, and make the floor heating is uniform, the deformation is small, the bedroom thermal efficiency is higher. This is the recommended laying method for current values.

"Can you add plywood or joiners to the floor?"

First of all, the heating of the heat of the plywood or below the floor laid joinery board, is not conducive to heat conduction, virtually increase the quantity of heat in the conduction process and loss, increase the geothermal heating system of heating costs. Second, when the choose and buy the plate quality closes nevertheless, can also lead to indoor free of formaldehyde, or because of its moisture content is not up to standard, moisture is absorbed by the floor after laid, and cause of the arch since the floor tile change, wait for a phenomenon, together with the base material plate is more harm than good, really is self-defeating, gild the lily. The floor is not allowed to pave the floor.

"is floor mat with aluminium film used for floor heating?"

This is typically misleading. Practice has proved that: floor radiation heating system, heat transfer, radiation, followed by convection, the last is conduction, if in the heat the ground cover aluminum foil, formed the radiation, in keeping the heating floor surface temperature of the same circumstances, with aluminium film foam pad its thermal resistance is big, small and ordinary foam mat thermal resistance. It is obvious that the common foam cushion is better than the foam pad with aluminium film, which is more conducive to heat transfer from the floor to the bedroom. Accordingly, the user should choose heat resistance small, moistureproof, the material cushion that is resistant to decay is laid when buying the floor of floor heating.

No floor heating test will be done after floor paving.

After the installation of the geothermal heating floor, in addition to the routine inspection and acceptance, the most important is to conduct temperature rise and acceptance of the floor. When the floor is finished or after winter heating, the first heating system should be heated slowly. When the base ground heats up to 25, it should be constant for 12 to 24 hours. After that, the indoor temperature (14-22) should be set at a slow temperature of 1 /h. The temperature should not be too high and the surface temperature of the wood floor should be 28. In short time, the limit temperature is 32. The higher the temperature, the greater the loss of thermal energy, the shorter the life of the thermal system, the more likely to be hidden trouble, and the floor is prone to the deformation of the bag, twist, bend and crack.

The floor shop is completed without environmental acceptance.

Are used as a floor heating system on the floor is the compound floor and real wood compound, aggrandizement wood floor,) and formaldehyde release a quantity to problems in itself, and when it's as the geothermal floor, after heating, the more aggravated the release of formaldehyde. In after the shop is the heating of the heat of the floor, therefore, must be done on the acceptance of environmental protection, to ensure the free formaldehyde to release a quantity to reach the standard (national standard of 1.5 mg/L), in order to make the floor can be normal use, be sure to do two points: when buying shop floor heating floor should be done before the environment detects, general measurement inspection is free, management fees, after the shop is good then inspection for acceptance of environmental protection. The floor and auxiliary material environmental protection index must reach the standard. You can't buy a cheap, eco-friendly bargain.

On the floor, there are no legs assembled furniture or carpet, which can destroy the heat sink surface of the floor.

Along with the continuous improvement of living standards, the modern people pursuit for household decorates is more and more personalized, hence also arises at the historic moment many personalized furniture assemblies, which can be assembled arbitrarily according to master be fond of. However, the furniture is often the bare - leg furniture that is directly exposed to the ground. If its indoor shop is geothermal heating floor, its furniture, carpet and floor directly to cover large area, makes the floor away due to heat, excessive concentration of lead to uneven floor heating, cause deformation of the floor appears here, and so on and so forth, waste heat, make the bedroom temperature decrease.

没有评论:

发表评论

Request For Quotation

GET FREE SAMPLES AND CATALOG


Note: If you can provide the following data in the mail, you will be provided with a quick quote and detailed specifications soon:

1) What type of product is needed? (such as floors, wall panels, fences, etc.)
2) What is the maximum demand in meters or square meters? For example, 100m? 200 square meters?
3) What is the product model you need? (Individual products have no product model)
4) In which areas do you need to use the product? Family use or agency sales?

Thank you for your interest in Seven Trust's wood-based products. Please feel free to submit your enquiry to us. Our sales manager will contact you as soon as possible.